Welcome to visit Kunshan Haien Electrical Co.,Ltd. Official website! Site Map | 
Kunshan Haien Electrical Co.,Ltd.

Engaged in industries such as electrical instruments, oil stations, etc

Hotline0512-57787475-800
Modular instrument
KSA-2000-EX series explosion-proof isolation safety barrier
KSA-2000-EX series explosion-proof isolation safety barrier

KSA-2000-EX series explosion-proof isolation safety barrier

The KSA-2000-EX series explosion-proof isolation safety barrier is an intrinsically safe explosion-proof electrical product designed according to the requirements of GB3836 and IEC61508 standards. The product uses high-quality semiconductor devices and SMT surface mount technology, and is widely used in intrinsically safe explosion-proof systems such as petroleum, chemical, metallurgical, and power industries.

OnlineHotline
0512-57787475-800

overview

The KSA-2000-EX series explosion-proof isolation safety barrier is an intrinsically safe explosion-proof electrical product designed according to the requirements of GB3836 and IEC61508 standards. The product uses high-quality semiconductor devices and SMT surface mount technology, and is widely used in intrinsically safe explosion-proof systems such as petroleum, chemical, metallurgical, and power industries. Not only can it be used in conjunction with various two - and three wire transmitters, two-wire intelligent (HART) transmitters, intelligent (HART) electromagnetic flow meters, electrical converters, electrical valve positioners, intrinsic safety solenoid valves, level switches, NAMUR proximity switches, symbol fieldbus (FF) protocol intrinsic safety instruments manufactured by multiple domestic and foreign instrument companies, but it can also be used in conjunction with simple equipment such as dry contact switches, thermocouples (J, K, T, E, B, S, etc.), strain gauges, and thermal resistors (Pt100).

ATEX

National Instrumentation Explosion proof Safety Supervision and Inspection Station (NEPSI) certification

Explosion proof mark: [Ex ia Ga] II C

2、 General Technical Parameters

Power supply: Reverse protection for 18V DC to 32V DC power supply

Working power consumption: ≤ 0.7W (24V, single full load output) ≤ 1.3W (24V, dual full load output)

Input signal: K. Thermocouples such as E, S, B, J, T, R, N, etc

Thermal resistors such as Pt100, Cu100, Cu50, BA1, BA2, etc

0/4-20mA, HATR digital signal

1-5V (0-5V, 0/2-10V)

Dry contact or collector open circuit

Frequency pulse signal (range needs to be specified when ordering)

2-wire and 3-wire potentiometers with a resistance range of 0k Ω to 10k Ω

Lead resistance: ≤ 20 Ω/wire (thermal resistance)

Output signal: Current output: 0/4~20mA

Voltage output: 0/1-5V, 0/2-10V

(* Note: Users need to select current or voltage output when placing an order, default current output is 4-20mA)

Allowable load: Current: 0/4~20mA RL ≤ 550 Ω

Voltage: 0/1-5V/RL ≥ 1M Ω; 0/2~10V / RL ≥2MΩ

Conversion accuracy: 0.1% F.S

Compensation accuracy: 1 ℃ (compensation temperature range:- 20℃~+60℃)  

Temperature drift: 40ppm/℃

Response time: ≤ 500ms

Electromagnetic compatibility: compliant with GB/T18268 (IEC61326)

Dielectric strength: ≥ 2500V AC (local and non local)

≥ 1500V AC (between non local terminals)

Insulation resistance: ≥ 100M Ω (between input/output/power supply)

Working temperature:- 20℃~+60℃

Specification and dimensions: Width 17.8mm, Height 110mm, Depth 119mm

Panel Description: PWR: Green power indicator, ALM: Red fault indication

Fault status: Input disconnected, LED flashing; Input out of range, LED stays on. When the input is disconnected or exceeds the range, the output current can be set within the range of 0~22mA (default to follow the input)

Application location: Can connect to Zone 0, Zone 1, and Zone 2; II A、II B、II C; Intrinsic safety equipment in danger zones T4 to T6

Storage temperature -40 ℃ to+80 ℃

Relative humidity 35%~85% RH

3、 List of Safety Barrier Selection

Type

Model

Number of channels

Types of danger zone signals

Safe zone signal type

notes

Switching input

KSA-2011-EX

One in, one out

Switch, proximity switch

Relay

Wire breakage detection function

KSA-2012-EX

Two in, two out

KSA-2013-EX

One in, two out

KSA-2014-EX

Three in, three out

KSA-2015-EX

Four in, four out

Switching Output

KSA-2021-EX

One in, one out

When the driving current is 35mA

Dry contact input

Circuit output control

KSA-2022-EX

Two in, two out

Output voltage ≥ 12V

KSA-2023-EX

One in, one out

When the driving current is 45mA

KSA-2024-EX

Two in, two out

Output voltage ≥ 12V

KSA-2025-EX

One in, one out

When the driving current is 60mA

KSA-2026-EX

Two in, two out

Output voltage ≥ 12V

analog input

KSA-2035-EX

One in, two out

2、 Three wire transmitter, current source input

4~20mA/0~20mA

Three isolation of power supply, input, and output

KSA-2036-EX

Two in, two out

1~5V/0~5V output

KSA-2037-EX

Two in, two out

Two wire transmitter input

4~20mA

Input and output isolation

HART Digital signal output

KSA-2045-EX

One in, one out

2、 Three wire transmitter, current

Source, HART digital signal input


4~20mA/0~20mA

Three isolation of power supply, input, and output

1~5V/0~5V

HART Digital signal output

KSA-2047-EX

One in, one out

2、 Three wire transmitter, current source input

4~20mA/0~20mA

1~5V/0~5V output

analog output

KSA-2038-EX

Two in, two out

4~20mA/0~20mA

4~20mA/0~20mA input

Independent power supply

KSA-2067-EX

One in, one out

1-5V/0-5V output

Analog input and output

KSA-2039-EX

Two in, two out

Channel 1:4~20mA input

Channel 1:4~20mA input

One 4-20mA input

One 4-20mA output


Channel 2: 4-20mA input

Channel 2: 4-20mA input

Thermal resistance input

KSA-2071-EX

One in, one out

Thermal resistance input

4~20mA/1~5V output

Independent power supply

Thermocouple Input

KSA-2072-EX

One in, one out

Thermocouple Input

Programmable

Thermal resistance input

KSA-2073-EX

One in, one out

Thermal resistance input

Millivolt signal input

KSA-2081-EX

One in, one out

Millivolt signal input

Corresponding millivolt signal output

1: 1 millivolt input/output

Tags: All