Welcome to visit Kunshan Haien Electrical Co.,Ltd. Official website! Site Map | 
Kunshan Haien Electrical Co.,Ltd.

Engaged in industries such as electrical instruments, oil stations, etc

Hotline0512-57787475-800
High and low voltage control cabinet
GCK low-voltage withdrawable switchgear

GCK low-voltage withdrawable switchgear

HNGCK low-voltage withdrawable switchgear is widely used in power distribution centers PC and motor control centers MCC of power plants, substations, factories, mining enterprises, and high-rise buildings. It is a low-voltage complete distribution device used for centralized control of power distribution and motors, reactive power compensation in power generation and supply systems with AC 50-60Hz, rated working voltage of 660V and below, and rated current of 4000A and below.

OnlineHotline
0512-57787475-800

  HNGCK low-voltage withdrawable switchgear is widely used in power distribution centers PC and motor control centers MCC of power plants, substations, factories, mining enterprises, and high-rise buildings. It is a low-voltage complete distribution device used for centralized control of power distribution and motors, reactive power compensation in power generation and supply systems with AC 50-60Hz, rated working voltage of 660V and below, and rated current of 4000A and below.

Main technical parameters

Rated insulation voltage: AC 660V, AC 1000V

Rated working voltage: AC 380 V, AC 660 V

Rated frequency: 50Hz

Maximum current of feeding circuit: 3150A

Maximum current of drawer circuit: 3150A

Maximum capacity of control motor: 320KW

Peak withstand current of horizontal busbar (0.1S): 63KA, 105KA, 176KA

Short time withstand current of horizontal busbar (1S): 30 KA, 50 KA, 80 KA, 100 KA

Vertical bus peak withstand current (0.1S): 63 KA, 105 KA

Short time withstand current of vertical busbar (1S): 30 KA, 50 KA

Rated power frequency withstand voltage (1min): 2500V

Secondary power frequency withstand voltage (1min): 2500V

Protection level: IP30、IP40

Dimensions: Width * Depth * Height mm: 600 (800, 1000) * 800 (1000) * 2200

 

Product usage environment

  1. The ambient air temperature shall not exceed+40 ℃, not be lower than -5 ℃, and the average temperature within 24 hours shall not exceed+35 ℃. If it exceeds, the capacity shall be reduced according to the actual situation for operation;

  2. Indoor use: The altitude of the usage location shall not exceed 2000m

  3. When the relative temperature of the surrounding air is+40 ℃, it should not exceed 50%. At lower temperatures, a larger relative temperature is allowed, such as 90% at+20 ℃. It should be considered that condensation may occur accidentally due to temperature changes;

  4. When installing the device, the slope with respect to the vertical plane should not exceed 5 ℃, and the entire cabinet row should be relatively flat (in accordance with GBJ232-82 standard);

  5. The device should be installed in a place without severe vibration and impact, and where there is insufficient corrosion to the electrical components;

  6. Users with special requirements can negotiate with the manufacturer to resolve them